TRI-ESS SCIENCES
1020 W. CHESTNUT STREET, BURBANK, CA 91506
24 hour Emergency: 800-535-5053
SECTION I—PRODUCT IDENTIFICATION
PRODUCT NAME:
SAFETY FUSEEMERGENCY TELEPHONE NUMBER: 313-654-6036
TELEPHONE NUMBER FOR INFORMATION: 313-654-6036
DATE PREPARED: 4-1-94
SECTION II – HAZARDOUS INGREDIENTS
BLACK POWDER - (POTASSIUM
NITRATE, CHARCOAL, SULFUR)
NOTE:
The black powder is enclosed in thread wrapping and coated with a
water resistant lacquer. No pyrotechnic composition is exposed.
SAFETY FUSE IS CLASSIFIED AS FUSE, SAFETY, UN0105, PG BY D.O.T.
SECTION III – PHYSICAL/CHEMICAL CHARACTERISTICS
BOILING POINT: N/A
SPECIFIC GRAVITY: N/A
VAPOR PRESSURE: (mm Hg): N/A
MELTING POINT: N/A
VAPOR DENSITY (AIR=1): N/A
EVAPORATION RATE (Butyl Acetate=1): N/A
SOLUBILITY IN WATER: SLIGHT
APPEARANCE AND ODOR: TWISTED THREAT COATED WITH GREEN OR RED LAQUER
SECTION IV - FIRE AND EXPLOSION HAZARD DATA
FLASH POINT (Method Used): IGNITION
TEMP: 330°C
FLAMMABLE LIMITS: N/A
LEL: N/A UEL: N/A
EXTINGUISHING METHOD: FLOOD WITH WATER
SPECIAL FIRE FIGHTING PROCEDURES:
SUFFOCATION METHODS WILL NOT WORK.
DO NOT CONFINE BULK AMOUNTS OR BURNING FUSE - ALLOW IT TO BURN OPEN.
UNUSUAL FIRE AND EXPLOSION
HAZARDS: END OF A SECTION OF FUSE CAN BE
IGNITED BY A MATCH, CIGARETTE OR OTHER BURNING OBJECT.
SECTION V—REACTIVE DATA
STABILITY: STABLE
CONDITIONS TO AVOID: NO SMOKING OR OPEN FLAMES IN VICINITY OF REELS OF
FUSE
INCOMPATAILITY (MATERIALS TO AVOID: EXPLOSIVE MATERIALS
HAZARDOUS DECOMPOSITION OR BY PRODUCTS: BURNING FUSE PRODUCES
CARBON
DIOXIDE AND SOME CARBON MONOXIDE.
HAZARDOUSE POLYMERIZATION: WILL NOT OCCUR
SECTION VI—HEALTH HAZARD DATA
ROUTES OF ENTRY: N/A
HEALTH HAZARDS (ACUTE & CHRONIC): N/A
CARCINOGENICITY: N/A
MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE: N/A
EMERGENCY AND FIRST AID PROCEDURES: N/A
SECTION VII—SPECIAL HANDLING INFORMATION
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED:
FUSE CAN BE PICKED UP AND REWOUND.
AVOID SMOKING OR OPEN FLAME IN VICINITY OF ANY FUSE.
WASTE DISPOSAL METHOD: BURN IN COMPLIANCE WITH FEDERAL AND
LOCAL REGULATIONS.
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORING:
AVOID SMOKING OR OPEN FLAMES. KEEP FUSE DRY TO INSURE PROPER FUNCTIONING.
SECTION VIII—
CONTROL MEASURESRESPIRATORY PROTECTION: NONE REQUIRED
VENTILATION: NONE REQUIRED
PERSONAL PROTECTION: NONE REQUIRED
WORK/HYGENIC PRACTICES: NO SMOKING, MATCHES OR FLAMES IN VICINITY
OF FUSE
While Tri-Ess Sciences Inc. believes the information set forth herein is
accurate as of the date thereof, Tri-Ess Sciences Inc. makes no warranty
with
respect thereto and expressly disclaims all liability for reliance
thereof, such
data is offered solely for your consideration, investigation
and your
verification.